Portable DC power supply for cathodic protection current-requirement tests, temporary protection and on/off potential surveys on pipelines, tanks and buried structures. Supplied by PetroMarys across the UAE, Saudi Arabia and the wider Middle East.

A compact, portable DC power source for impressed-current cathodic protection. Engineers use it to measure the protection current a structure needs, to protect pipelines and tanks temporarily, and to run on/off potential surveys with its built-in current interrupter.
The portable transformer rectifier gives cathodic protection engineers a reliable DC source wherever the job is: on a new pipeline route before permanent power arrives, at a tank farm during commissioning, or during an on/off potential survey. It runs from mains or a battery, holds output steady as soil conditions change, and switches on and off on a timed or GPS-synchronised cycle.
| Input supply | 220 V AC or 24 V DC |
|---|---|
| DC output voltage | 0–30 V (other ratings to order) |
| DC output current | 0–100 A (other ratings to order) |
| Output adjustment | 0–100%, continuously adjustable |
| Operating modes | Manual and automatic |
| Reference control range | −3 V to +3 V |
| Current control accuracy | ≤1% with load change |
| Potential control accuracy | ±10 mV with load change |
| Ripple | ≤2% at 100% rated output |
| Current interrupter | Local clock or GPS-synchronised (optional) |
| Display | Digital LCD or analogue pointer meters |
| Protection | Over-current, over-voltage, high temperature |
| Insulation resistance | Input and output to earth: min. 10 MΩ |
| Cooling | Air cooled |
|---|---|
| Enclosure protection | IP42 to IP55 |
| Operating temperature | −25 °C to +50 °C |
| Relative humidity | ≤90% |
| Installation tilt | ≤5° |
| Altitude | ≤2000 m |
| Hazardous areas | Not suitable. Non-hazardous locations only, away from flammable or explosive gases and highly corrosive atmospheres |
Typical structures: buried pipelines, storage tank bottoms, plant piping and water transmission mains.
It is a temporary DC power source for impressed-current cathodic protection. Engineers use it to measure the current a structure needs before designing a permanent system, to protect a structure for a short period, and to run on/off potential surveys.
A permanent transformer rectifier is installed on site for the life of the cathodic protection system, usually in a larger fixed enclosure. The portable unit is carried from site to site for testing and short-term protection.
No. It is designed for non-hazardous locations only and must not be used where flammable or explosive gases may be present.
When a pipeline is protected by more than one rectifier, all of them must switch off at the same moment to get a true instant-off potential. GPS synchronisation does this without cables between the units.
Yes. The standard range is up to 30 V and 100 A DC. Other ratings can be built to order. Enter your required voltage and current in the configurator above, or send us your specification.
PetroMarys supplies cathodic protection equipment across the UAE, Saudi Arabia, Oman, Qatar, Kuwait, Bahrain, Iraq and the wider Middle East, Africa and South Asia, including Pakistan and India.
Specifications are based on manufacturer data and may vary for custom builds. Our engineers will confirm final ratings with your offer.