Portable Transformer Rectifier

Portable DC power supply for cathodic protection current-requirement tests, temporary protection and on/off potential surveys on pipelines, tanks and buried structures. Supplied by PetroMarys across the UAE, Saudi Arabia and the wider Middle East.

PetroMarys
Portable Transformer Rectifier – Product datasheet · info@petromarys.com · +971 50 646 3066 · petromarys.com
Portable transformer rectifier for cathodic protection testing, in a rugged carry case
Portable transformer rectifier in a rugged carry case

A compact, portable DC power source for impressed-current cathodic protection. Engineers use it to measure the protection current a structure needs, to protect pipelines and tanks temporarily, and to run on/off potential surveys with its built-in current interrupter.

0–30 V · 0–100 A DCOutput, other ratings to order
220 V AC or 24 V DCMains or battery input
±10 mV · ≤1%Potential / current control accuracy
GPS-synchronisedCurrent interrupter (optional)

Configure your unit

Choose the options you need. Your order code updates as you go.

Input supply
DC output rating

Standard range up to 30 V and 100 A DC.

Display
Current interrupter
Enclosure protection
Your order codePM-PTR-AC-30V30A-D-LC-IP42

The portable transformer rectifier gives cathodic protection engineers a reliable DC source wherever the job is: on a new pipeline route before permanent power arrives, at a tank farm during commissioning, or during an on/off potential survey. It runs from mains or a battery, holds output steady as soil conditions change, and switches on and off on a timed or GPS-synchronised cycle.

Key features

  • 0–30 V / 0–100 A DC output
  • 220 V AC or 24 V DC input
  • Manual and automatic operation
  • Potential held to ±10 mV
  • Current held to within 1%
  • Local or GPS-synchronised interrupter
  • Ripple ≤2% at full output
  • Over-current, over-voltage and over-temperature protection
  • Rugged carry case
  • −25 °C to +50 °C operation

Specifications

Electrical

Input supply220 V AC or 24 V DC
DC output voltage0–30 V (other ratings to order)
DC output current0–100 A (other ratings to order)
Output adjustment0–100%, continuously adjustable
Operating modesManual and automatic
Reference control range−3 V to +3 V
Current control accuracy≤1% with load change
Potential control accuracy±10 mV with load change
Ripple≤2% at 100% rated output
Current interrupterLocal clock or GPS-synchronised (optional)
DisplayDigital LCD or analogue pointer meters
ProtectionOver-current, over-voltage, high temperature
Insulation resistanceInput and output to earth: min. 10 MΩ

Mechanical and environment

CoolingAir cooled
Enclosure protectionIP42 to IP55
Operating temperature−25 °C to +50 °C
Relative humidity≤90%
Installation tilt≤5°
Altitude≤2000 m
Hazardous areasNot suitable. Non-hazardous locations only, away from flammable or explosive gases and highly corrosive atmospheres

What we need for a quote

  • Output voltage and current, or your order code
  • Input supply available on site
  • GPS-synchronised interruption needed or not
  • Quantity and delivery location
  • Any project or client specification

Applications

Current-requirement testsMeasure the current a pipeline or tank needs before designing the permanent system.
Temporary protectionProtect a structure during construction, or until the permanent transformer rectifier is commissioned.
Commissioning and troubleshootingCheck impressed-current systems and find under-protected sections.
Potential surveysOn/off and instant-off potential readings, using the built-in interrupter.

Typical structures: buried pipelines, storage tank bottoms, plant piping and water transmission mains.

Oil & gasRefining & petrochemicalGas distributionWater & wastewaterPower & desalinationDistrict cooling

Downloads

Factory inspection reportAvailable on request

Frequently asked questions

What is a portable transformer rectifier used for?

It is a temporary DC power source for impressed-current cathodic protection. Engineers use it to measure the current a structure needs before designing a permanent system, to protect a structure for a short period, and to run on/off potential surveys.

How is it different from a permanent transformer rectifier?

A permanent transformer rectifier is installed on site for the life of the cathodic protection system, usually in a larger fixed enclosure. The portable unit is carried from site to site for testing and short-term protection.

Can it be used in hazardous areas?

No. It is designed for non-hazardous locations only and must not be used where flammable or explosive gases may be present.

Why choose the GPS-synchronised interrupter?

When a pipeline is protected by more than one rectifier, all of them must switch off at the same moment to get a true instant-off potential. GPS synchronisation does this without cables between the units.

Can the output be customised?

Yes. The standard range is up to 30 V and 100 A DC. Other ratings can be built to order. Enter your required voltage and current in the configurator above, or send us your specification.

Which countries do you supply?

PetroMarys supplies cathodic protection equipment across the UAE, Saudi Arabia, Oman, Qatar, Kuwait, Bahrain, Iraq and the wider Middle East, Africa and South Asia, including Pakistan and India.

Specifications are based on manufacturer data and may vary for custom builds. Our engineers will confirm final ratings with your offer.